Toggle navigation
Metric
en
English
You are in:
Start
Diffusion
Long throw jet nozzles
KOO
KOO
Show all
Air supply grilles
Linear grilles
Linear floor grilles
Return grilles
Transfer grilles
External grilles
Rotational diffusers
Radial diffusers
Variable geometry diffusers
Linear slot diffusers
Floor diffusers
Long throw jet nozzles
Return diffusers
All
KAM
KOO
KAP
KOO
Length
300
450
600
750
900
1050
1200
Height
150
300
Projection angle
Line 1
0%
22%
45%
Projection
Vertical
0 º
Horizontal
1 Dir.
×
Ceiling plates
Results
Recommended velocities between: Vmin =2.5 m/s Vmax =12.5 m/s
Installation Data
Q:
m3/h
l/s
T. Room ºC
T.Supply ºC
Dt. ºC
Select with the recommended velocity
Coanda effect
Aerodynamic data
Afree (m2)
Ak (m2)
vf (m/s)
vk (m/s)
Dpt (pa)
AL0.2 (m)
AL0.3 (m)
AL0.5 (m)
AL0.7 (m)
AL1.1 (m)
AL1.5 (m)
T0.2 (ºC)
T0.3 (ºC)
T0.5 (ºC)
T0.7 (ºC)
T1.1 (ºC)
T1.5 (ºC)
bh0.2 (m)
bh0.3 (m)
bh0.5 (m)
bh0.7 (m)
bh1.1 (m)
bh1.5 (m)
bv0.2 (m)
bv0.3 (m)
bv0.5 (m)
bv0.7 (m)
bv1.1 (m)
bv1.5 (m)
bt0.2 (m)
bt0.3 (m)
bt0.5 (m)
bt0.7 (m)
bt1.1 (m)
bt1.5 (m)
Sound power level in dB (A) without regulator
Lw(dB(A)) >
Lw(dB(A)) <
Lw=Sound power level in dB (A). Note: Sound value without 10dB room attenuation
f(Hz)
63
125
250
500
1000
2000
4000
8000
global
Lw(dB(A))
×
Selection
×
Message